SHAFT KILNS
Model |
Temperature °C |
Inner sizes (mm) diameter height |
Outer sizes (mm) diameter height |
Power kW |
---|---|---|---|---|
HKRX 07.07-7 |
700 |
700 700 |
1400 1400 |
28 |
HKRX 07.1-7 |
700 |
700 1000 |
1400 1700 |
37 |
HKRX 1.08-7 |
700 |
1000 800 |
1700 1500 |
37 |
HKRX 1.1-7 |
700 |
1000 1000 |
1700 1700 |
44 |
HKRX 1.1,4-7 |
700 |
1000 1400 |
1700 2100 |
74 |
HKRX 1.2-7 |
700 |
1000 2000 |
1700 2700 |
74 |
HKRX 1,4.1,6-7 |
700 |
1400 1600 |
2100 2300 |
74 |
HKRX 1,4.2,2-7 |
700 |
1400 2200 |
2100 2900 |
99 |
HKRX 1,4.3-7 |
700 |
1400 3000 |
2100 3700 |
133 |
HKRX 1,8.2-7 |
700 |
1700 2000 |
2400 2700 |
99 |
HKRX 1,8.3-7 |
700 |
1700 3000 |
2400 3700 |
133 |
HKRX 1,8.3,5-7 |
700 |
1700 3500 |
2400 4250 |
182 |
- operational temperatures: 700 °C, 1100 °C, 1250 °C
- lid opening:
- manual
- hydraulic
- heating system:
- electric
- gas
- heating insulation made of materials with high thermal resistance, optimized for operational conditions and technology
- thermal process in active or protection atmoshere
- multi-zone control
- forced atmosphere circulation
- circulation fan power control
- different control systems upon request
- batch loading tools
- made-to-measure options
- heating power informative only, adapted to the specific needs of the customer